ManufacturerGEWISS
Part number / MPNGWD9362
Price & lead timeConfirmed during RFQ review; no stale public value shown
Technical statusEvidence requested with RFQ
Source checkedJul 2, 2026

Official model record

MSX 400 - MCCB - THERMAL ADJUSTABLE - MAGNETIC ADJUSTABLE - 36kA 3P+N 400A 690V

Description
Interruttore automatico scatolato
Code
MSX 400
No. of poles
3P+N
Rated current
400 A
Release
Electromechanic
ELECTRICAL CHARACTERISTICS
-
MECHANICAL CHARACTERISTICS
-
Standard
IEC/EN 60947-2
Execution
Fixed - Plug-in
Use category
A
DIN rail mounting
No
Rated frequency (Hz)
50 / 60
Can be equipped with motor operator
Yes
Rated operating voltage (Ue)
690 V ac - 250 V dc
Compatible interlock
Lever - Cable
Rated impulse withstand voltage (Uimp)
8 kV
Terminals supplied
Front FC
Overvoltage category
IV
Assembly position
Any
Insulation voltage (Ui)
800 V
Upline/downline power supply
Yes
Thermal regulation
0,63 - 0,8 - 1 x In
Electrical life (415Vac)
4.500 cycles
Magnetic regulation
6 - 8 - 10 - 12 x In
Mechanical life
15.000 cycles
Neutral protection
Not protected
Operating temperature
-5°C +65°C
Total power loss
89.6 W
Stocking temperature
-20° +65°
Rated short-circuit current making capacity (Icm)
-
Weight (kg)
5.6
Rated short-time withstand current for 0,3s (Icw)
-
Width
185 mm
Idn regulation
-
Height
260 mm
DT regulation
-
Depth
103 mm
SERVICE BREAKING CAPACITY (ICU)
-
RATED BREAKING CAPACITIY (ICS)
-
220/240Vac
50 kA

Source: Official GEWISS model product record. Ordering-code suffixes and current manufacturer revisions must still be checked before release.

Sourcing record

Product and identification context

GEWISS GWD9362 is identified by the manufacturer's official product record as “MSX 400 - MCCB - THERMAL ADJUSTABLE - MAGNETIC ADJUSTABLE - 36kA 3P+N 400A 690V”. The official record publishes model-specific fields including Description, Code, No. of poles, Rated current, Release, ELECTRICAL CHARACTERISTICS. Values shown on this page are transcribed from that source and should be checked against the current manufacturer document and the complete ordering code before purchase.

Manufacturer's official product information

Substitution control

Verify before order

  • Rated voltage, current, frequency and number of poles
  • Device function, utilization category and trip or fuse characteristic
  • Terminal type, conductor range and mounting method
  • Breaking capacity, protection rating and coordination requirements
  • Applicable approvals, standards and accessory compatibility

No unverified voltage, pressure, dimension, material or performance value is assigned on this page.