Exact manufacturer reference

GEWISS GWD4235

Request current identity, condition, availability, lead-time and delivery review for this catalog reference.

Catalog identity record GEWISS GWD4235 No unverified product photograph is presented as technical evidence.
Model data verified
ManufacturerGEWISS
Part number / MPNGWD4235
Price & lead timeConfirmed during RFQ review; no stale public value shown
Technical statusEvidence requested with RFQ
Source checkedJul 2, 2026

Official model record

RESIDUAL CURRENT CIRCUIT BREAKER - IDP - 2P 40A TYPE A[S] SELECTIVE Idn=0,5A - 2 MODULES

Description
RESIDUAL CURRENT CIRCUIT BREAKER
Code
IDP
No. of poles
2P
No. modules
2
Rated current
40 A
Rated residual operating current
500 mA
Type
A[S]
Rated voltage (EN/IEC 61008-1, 61008-2-1)
230/240 V
Standard
IEC/EN 61008-1, IEC/EN 61008-2-1
Rated frequency (Hz)
50/60 Hz
Insulation voltage (Ui)
500 V
Rated impulse withstand voltage (Uimp)
4 kV
Overvoltage category
III
Level of immunity (8/20 μs)
3000 A
Section rigid cable
<=1x35 - <=2x16 - <=1x16+2x10 mm²
Section flexible cable
<=1x35 - <=2x16 - <=1x16+2x10 mm²
Rated tightening torque
3 Nm
Double connection
YES (up stream and down stram)
Operating temperature
-25 +60°C (˃ 40°C with derating)
Stocking temperature
-40°C ÷ +70°C
Electrical endurance
≥ 10.000
Mechanical endurance
≥ 20000
Auxiliaries compatibility
Yes
ReStart compatibility
Yes
Assembly position
Any
Ware Number
85362010

Source: Official GEWISS model product record. Ordering-code suffixes and current manufacturer revisions must still be checked before release.

Sourcing record

Product and identification context

GEWISS GWD4235 is identified by the manufacturer's official product record as “RESIDUAL CURRENT CIRCUIT BREAKER - IDP - 2P 40A TYPE A[S] SELECTIVE Idn=0,5A - 2 MODULES”. The official record publishes model-specific fields including Description, Code, No. of poles, No. modules, Rated current, Rated residual operating current. Values shown on this page are transcribed from that source and should be checked against the current manufacturer document and the complete ordering code before purchase.

Manufacturer's official product information

Substitution control

Verify before order

  • Rated voltage, current, frequency and number of poles
  • Device function, utilization category and trip or fuse characteristic
  • Terminal type, conductor range and mounting method
  • Breaking capacity, protection rating and coordination requirements
  • Applicable approvals, standards and accessory compatibility

No unverified voltage, pressure, dimension, material or performance value is assigned on this page.