Exact manufacturer reference

GEWISS GW95448

Request current identity, condition, availability, lead-time and delivery review for this catalog reference.

Catalog identity record GEWISS GW95448 No unverified product photograph is presented as technical evidence.
Model data verified
ManufacturerGEWISS
Part number / MPNGW95448
Price & lead timeConfirmed during RFQ review; no stale public value shown
Technical statusEvidence requested with RFQ
Source checkedJul 2, 2026

Official model record

ADD ON RESIDUAL CURRENT CIRCUIT BREAKER FOR MTHP CIRCUIT BREAKER - 3P 100A TYPE A INSTANTANEOUS Idn=0,3A - 6 MODULES

Description
HIGH PERFORMANCE RESIDUAL CURRENT DEVICE
Code
BDHP
No. of poles
3P
No. modules
6
Rated current
100 A
Rated residual operating current
300 mA
Type
A
Rated voltage (IEC/EN 61009-1 app. G, IEC/EN 61009-2-1 app. G)
400 V
Standard
IEC/EN 61009-1 app. G, IEC/EN 61009-2-1 app. G
Rated frequency (Hz)
50/60 Hz
Insulation voltage (Ui)
500 V
Rated impulse withstand voltage (Uimp)
4 kV
Overvoltage category
III
Level of immunity (8/20 μs)
250 A
Section rigid cable
Max 70 mm²
Section flexible cable
Max 50 mm²
Operating temperature
-25 +40 °C
Stocking temperature
-40°C ÷ +70°C
Rated tightening torque
3.5 / 3 (terminals)
Assembly position
Any
Ware Number
85362090

Source: Official GEWISS model product record. Ordering-code suffixes and current manufacturer revisions must still be checked before release.

Sourcing record

Product and identification context

GEWISS GW95448 is identified by the manufacturer's official product record as “ADD ON RESIDUAL CURRENT CIRCUIT BREAKER FOR MTHP CIRCUIT BREAKER - 3P 100A TYPE A INSTANTANEOUS Idn=0,3A - 6 MODULES”. The official record publishes model-specific fields including Description, Code, No. of poles, No. modules, Rated current, Rated residual operating current. Values shown on this page are transcribed from that source and should be checked against the current manufacturer document and the complete ordering code before purchase.

Manufacturer's official product information

Substitution control

Verify before order

  • Rated voltage, current, frequency and number of poles
  • Device function, utilization category and trip or fuse characteristic
  • Terminal type, conductor range and mounting method
  • Breaking capacity, protection rating and coordination requirements
  • Applicable approvals, standards and accessory compatibility

No unverified voltage, pressure, dimension, material or performance value is assigned on this page.