Exact manufacturer reference

GEWISS GW95236

Request current identity, condition, availability, lead-time and delivery review for this catalog reference.

Catalog identity record GEWISS GW95236 No unverified product photograph is presented as technical evidence.
Model data verified
ManufacturerGEWISS
Part number / MPNGW95236
Price & lead timeConfirmed during RFQ review; no stale public value shown
Technical statusEvidence requested with RFQ
Source checkedJul 2, 2026

Official model record

COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 100 - 2P CURVE C 10A TYPE A Idn=0,3A - 2 MODULES

Description
RCCB WITH OVERCURRENT PROTECTION
Code
MDC 100
No. of poles
2P
No. modules
2
Rated current
10 A
Rated residual operating current
300 mA
Type
A
Curve
C
Rated voltage (IEC/EN 61009-1, 61009-2-1)
230/240 V
Energy limiting class
3
Standard
IEC/EN 61009-1, IEC/EN 61009-2-1
Rated frequency (Hz)
50/60 Hz
Breaking capacity IEC/EN 61009-1 230V (Icn)
10000 A
Breaking capacity IEC/EN 61009-1 (Ics)
0.75 x Icn
Breaking capacity IEC/EN 60947-2 230V (Icu)
15 kA
Breaking capacity IEC/EN 60947-2 (Ics)
50% Icu
Insulation voltage (Ui)
500 V
Level of immunity (8/20 μs)
250 A
Rated impulse withstand voltage (Uimp)
4 kV
Overvoltage category
III
Electrical endurance
10.000
Mechanical endurance
20.000
Section rigid cable
<=1x35 - <=2x16 - <=1x16+2x10 mm²
Section flexible cable
<=1x35 - <=2x16 - <=1x16+2x10 mm²
Double connection
YES (only down stream)
Rated tightening torque
2 Nm
Operating temperature
-25 +60° C (derating of In with T>30° C)
Stocking temperature
-40°C ÷ +70°C
Auxiliaries compatibility
Yes
ReStart compatibility
Yes
Assembly position
Any
Ware Number
85362010

Source: Official GEWISS model product record. Ordering-code suffixes and current manufacturer revisions must still be checked before release.

Sourcing record

Product and identification context

GEWISS GW95236 is identified by the manufacturer's official product record as “COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 100 - 2P CURVE C 10A TYPE A Idn=0,3A - 2 MODULES”. The official record publishes model-specific fields including Description, Code, No. of poles, No. modules, Rated current, Rated residual operating current. Values shown on this page are transcribed from that source and should be checked against the current manufacturer document and the complete ordering code before purchase.

Manufacturer's official product information

Substitution control

Verify before order

  • Rated voltage, current, frequency and number of poles
  • Device function, utilization category and trip or fuse characteristic
  • Terminal type, conductor range and mounting method
  • Breaking capacity, protection rating and coordination requirements
  • Applicable approvals, standards and accessory compatibility

No unverified voltage, pressure, dimension, material or performance value is assigned on this page.