Exact manufacturer reference

GEWISS GW94207

Request current identity, condition, availability, lead time and delivery review for this catalog reference.

Catalog identity record GEWISS GW94207 No unverified product photograph is presented as technical evidence.
Model data verified
U.S. commercial desk Fairfield, New Jersey Response target Within 24 hours Delivery review Nationwide and worldwide
ManufacturerGEWISS
Part number / MPNGW94207
Price & lead timeConfirmed during RFQ review; no stale public value shown
Technical statusEvidence requested with RFQ
Source checkedJul 2, 2026
U.S. quote lane Price, availability and lead time within 24 hours
Exact reference GEWISS · GW94207
Identity Condition Best route Quote
No order is placed. Your request starts a written commercial review.

Procurement answer summary

What this page confirms about GEWISS GW94207

Exact reference

GEWISS GW94207

Procurement use

Industrial RFQ sourcing for electrical, safety & connectivity price, availability, condition, lead time and delivery review.

Evidence status

Model data verified

Technical boundary

Model-specific ratings, dimensions, compatibility and revisions are not guessed; they are confirmed from manufacturer evidence, nameplate photos, drawings, BOM lines or supplied documents.

Response path

Submit quantity, destination and any nameplate, datasheet or BOM evidence for a written response within 24 hours.

Official model record

COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 45 - 1P+N CURVE C 16A TYPE A Idn=0,03A - 2 MODULES

Description
RCCB WITH OVERCURRENT PROTECTION
Code
MDC 45
No. of poles
1P+N
No. modules
2
Rated current
16 A
Rated residual operating current
30 mA
Type
A
Curve
C
Rated voltage (IEC/EN 61009-1, 61009-2-1)
230/240 V
Energy limiting class
3
Standard
IEC/EN 61009-1, IEC/EN 61009-2-1
Rated frequency (Hz)
50/60 Hz
Breaking capacity IEC/EN 61009-1 230V (Icn)
4500 A
Breaking capacity IEC/EN 61009-1 (Ics)
1 x Icn
Breaking capacity IEC/EN 60947-2 230V (Icu)
6 kA
Breaking capacity IEC/EN 60947-2 (Ics)
100% Icu
Insulation voltage (Ui)
500 V
Level of immunity (8/20 μs)
250 A
Rated impulse withstand voltage (Uimp)
4 kV
Overvoltage category
III
Electrical endurance
10.000
Mechanical endurance
20.000
Section rigid cable
<=1x35 - <=2x16 - <=1x16+2x10 mm²
Section flexible cable
<=1x35 - <=2x16 - <=1x16+2x10 mm²
Double connection
YES (only down stream)
Rated tightening torque
2 Nm
Operating temperature
-25 +60° C (derating of In with T>30° C)
Stocking temperature
-40°C ÷ +70°C
Auxiliaries compatibility
Yes
ReStart compatibility
Yes
Assembly position
Any
Ware Number
85362010

Source: Official GEWISS model product record. Ordering-code suffixes and current manufacturer revisions must still be checked before release.

Sourcing record

Product and identification context

GEWISS GW94207 is identified by the manufacturer's official product record as “COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 45 - 1P+N CURVE C 16A TYPE A Idn=0,03A - 2 MODULES”. The official record publishes model-specific fields including Description, Code, No. of poles, No. modules, Rated current, Rated residual operating current. Values shown on this page are transcribed from that source and should be checked against the current manufacturer document and the complete ordering code before purchase.

Electrical, Safety & Connectivity provides the functional catalog context for this manufacturer. It does not replace model-level documentation.

Manufacturer's official product information

Substitution control

Verify before order

  • Rated voltage, current, frequency and number of poles
  • Device function, utilization category and trip or fuse characteristic
  • Terminal type, conductor range and mounting method
  • Breaking capacity, protection rating and coordination requirements
  • Applicable approvals, standards and accessory compatibility

No unverified voltage, pressure, dimension, material or performance value is assigned on this page.