Exact manufacturer reference

GEWISS GW66224N

Request current identity, condition, availability, lead-time and delivery review for this catalog reference.

Catalog identity record GEWISS GW66224N No unverified product photograph is presented as technical evidence.
Model data verified
ManufacturerGEWISS
Part number / MPNGW66224N
Price & lead timeConfirmed during RFQ review; no stale public value shown
Technical statusEvidence requested with RFQ
Source checkedJul 2, 2026

Official model record

VERTICAL FIXED INTERLOCKED SOCKET OUTLET - WITH BOTTOM - WITH FUSE-HOLDER BASE - 3P+E 16A 100-130V - 50/60HZ 4H - IP67

Type of fuse
Ø 10.3x38 mm
Type
Vertical
Fuse breacking capacity
> 50 kA
Thermo-pressure with ball
125 °C (IB socket) - 80 °C (bottom)
Rated insulation voltage (Ui)
500 V
IP degree
IP67
No. of poles
3P+E
Mechanical resistance
IK08
Frequency
50/60 Hz
Operating temperature
-25 +40 °C
Protection
Fuse-holder base (CBF)
With back-mounting box
Yes
Electrocod
2222
Glow wire test
850 °C (IB socket) - 650 °C (bottom)
Colour
Yellow
Breaking capacity (Icc)
10 kA
Weight
Max. 1.0 Kg
IB socket outlet rated current (In)
15 A
Rated impulse withstand voltage (Uimp)
4 kV
Rated current (A)
16
Reference h
4
Rated voltage
100 - 130 V
Ware Number
85366990

Source: Official GEWISS model product record. Ordering-code suffixes and current manufacturer revisions must still be checked before release.

Sourcing record

Product and identification context

GEWISS GW66224N is identified by the manufacturer's official product record as “VERTICAL FIXED INTERLOCKED SOCKET OUTLET - WITH BOTTOM - WITH FUSE-HOLDER BASE - 3P+E 16A 100-130V - 50/60HZ 4H - IP67”. The official record publishes model-specific fields including Type of fuse, Type, Fuse breacking capacity, Thermo-pressure with ball, Rated insulation voltage (Ui), IP degree. Values shown on this page are transcribed from that source and should be checked against the current manufacturer document and the complete ordering code before purchase.

Manufacturer's official product information

Substitution control

Verify before order

  • Rated voltage, current, frequency and number of poles
  • Device function, utilization category and trip or fuse characteristic
  • Terminal type, conductor range and mounting method
  • Breaking capacity, protection rating and coordination requirements
  • Applicable approvals, standards and accessory compatibility

No unverified voltage, pressure, dimension, material or performance value is assigned on this page.