Exact manufacturer reference

GEWISS GW12248

Request current identity, condition, availability, lead-time and delivery review for this catalog reference.

Catalog identity record GEWISS GW12248 No unverified product photograph is presented as technical evidence.
Model data verified
ManufacturerGEWISS
Part number / MPNGW12248
Price & lead timeConfirmed during RFQ review; no stale public value shown
Technical statusEvidence requested with RFQ
Source checkedJul 2, 2026

Official model record

FRENCH STANDARD SOCKET-OUTLET 250V ac - FRONT TIGHTENING TERMINALS - 2P+E 16A - 2 MODULES - SATIN BLACK - CHORUSMART

Category
Socket-outlet
Description
2P+E - 16 A
Colour
Satin black
Voltage
250 V ac
Standard
French, IEC 60884-1; NF C 61-314
Characteristics
With safety shutters
For plug pins
Ø 4 / 4.8 mm
Wiring terminals
Screws with front tightening terminals
Resistance at test voltage
2000 V at 50 Hz for 1 minute
Insulation resistance
> 5 MOhm
Prolonged operation socket (no.of position changes)
10.000 at In 250 V ac cosφ=0,8
Thermo-pressure with ball
125 °C
Glow Wire Test
850 °C
Terminal grip on cable traction
> 50 N
Terminal tightening capacity stranded cables (mm²)
min. 0,75 - max. 2x4
Terminal tightening capacity solid cables (mm²)
min. 0,5 - max. 2x2,5
No. modules
2
Electrocod
0131
Material
Technopolymer
Ware Number
85366990

Source: Official GEWISS model product record. Ordering-code suffixes and current manufacturer revisions must still be checked before release.

Sourcing record

Product and identification context

GEWISS GW12248 is identified by the manufacturer's official product record as “FRENCH STANDARD SOCKET-OUTLET 250V ac - FRONT TIGHTENING TERMINALS - 2P+E 16A - 2 MODULES - SATIN BLACK - CHORUSMART”. The official record publishes model-specific fields including Category, Description, Colour, Voltage, Standard, Characteristics. Values shown on this page are transcribed from that source and should be checked against the current manufacturer document and the complete ordering code before purchase.

Manufacturer's official product information

Substitution control

Verify before order

  • Rated voltage, current, frequency and number of poles
  • Device function, utilization category and trip or fuse characteristic
  • Terminal type, conductor range and mounting method
  • Breaking capacity, protection rating and coordination requirements
  • Applicable approvals, standards and accessory compatibility

No unverified voltage, pressure, dimension, material or performance value is assigned on this page.